A peptide’s sequence is the order of its amino acids, from the N-terminus to the C-terminus. Peptide sequencing is the job of reading that order from a real sample. Two methods do most of that work: Edman degradation, the classic chemical method, and tandem mass spectrometry (MS/MS), the method most labs rely on today. This guide explains how each one works, walks through a simple example, and covers what each method can and can’t show.
Why sequence order needs its own test
Several common tests check a peptide without reading its order. Amino acid analysis shows which amino acids are present and in what ratios, but two peptides with the same amino acids in a different order give the same result. Our guide to amino acid analysis of peptides explains that method. An intact mass measurement has the same blind spot: Gly-Ala-Ser and Ser-Ala-Gly have exactly the same mass. Sequencing is what tells them apart. For how sequences are written, see our guide to peptide sequence notation.
Edman degradation, step by step
Edman degradation was developed by the chemist Pehr Edman around 1950. It removes and identifies one amino acid at a time from the N-terminus, leaving the rest of the chain intact for the next round. Each cycle has three steps:
- Coupling. Under mildly basic conditions, the free amino group at the N-terminus reacts with phenyl isothiocyanate (PITC), also called Edman’s reagent. This forms a phenylthiocarbamoyl (PTC) peptide.
- Cleavage. An anhydrous acid, typically trifluoroacetic acid, breaks off only the first amino acid as an anilinothiazolinone (ATZ) derivative. The rest of the chain stays whole, with a new free N-terminus.
- Conversion and identification. The unstable ATZ derivative is converted in aqueous acid into a more stable phenylthiohydantoin (PTH) amino acid. HPLC then identifies it by comparing its retention time with PTH standards.
The cycle repeats on the shortened chain, so each round reads the next amino acid in order. Modern automated sequencers run these cycles without manual handling, typically in well under an hour per cycle.
Limits of Edman degradation
- It needs a free N-terminus. If the N-terminal amino group is blocked, for example by acetylation or by a pyroglutamate ring, the coupling step can’t happen and the method reads nothing.
- Read length is limited. Each cycle is slightly less than 100% efficient, so background signal builds up. In practice, reliable reads usually reach about 30 to 50 residues.
- It reads one sequence at a time. A mixture of peptides gives overlapping signals that are hard to interpret.
- Some residues are harder to call. Unusual or modified amino acids may not match any standard PTH peak.
Edman degradation vs Sanger’s method
Searches often pair Edman degradation with “Sanger sequencing”. Frederick Sanger’s earlier protein method labels the N-terminal amino acid with 1-fluoro-2,4-dinitrobenzene (Sanger’s reagent), then hydrolyzes the whole chain to identify it. That identifies only the first residue, because the rest of the chain is broken apart in the process. Edman’s key advance was removing one residue while keeping the rest of the chain intact. (The term “Sanger sequencing” today usually means a DNA sequencing method, which is a different technique.)
Tandem mass spectrometry (MS/MS)
Tandem mass spectrometry uses two stages of mass analysis. Our explainer on peptide molecular weight and mass spec covers how a peptide appears as an ion in the first place. In MS/MS:
- Stage 1: the instrument selects the ion of the intact peptide, called the precursor ion.
- Activation: the selected ion is broken apart, most often by collision with an inert gas (collision-induced dissociation, CID, or the related HCD). Other methods, such as electron-transfer dissociation (ETD), are also used.
- Stage 2: the instrument measures the masses of the resulting product ions.
Peptides tend to break along their peptide bonds. Pieces that keep the N-terminus are called b ions, and pieces that keep the C-terminus are called y ions. A series of b ions or y ions forms a ladder: the mass difference between neighboring peaks equals the mass of one amino acid residue. Reading those differences in order spells out the sequence.
A worked example
Here is an example with made-up numbers, not a real product. The values are calculated monoisotopic masses for singly charged ions of the four-residue peptide Gly-Ala-Leu-Phe. Its precursor ion ([M+H]+) is at m/z 407.23.
| Ion | Contains | m/z | Ion | Contains | m/z |
|---|---|---|---|---|---|
| b1 | Gly | 58.03 | y1 | Phe | 166.09 |
| b2 | Gly-Ala | 129.07 | y2 | Leu-Phe | 279.17 |
| b3 | Gly-Ala-Leu | 242.15 | y3 | Ala-Leu-Phe | 350.21 |
Reading the b ladder: 129.07 − 58.03 = 71.04, the residue mass of alanine, and 242.15 − 129.07 = 113.08, the residue mass of leucine (or isoleucine, see below). The y ladder reads the same sequence from the other end: 279.17 − 166.09 = 113.08 and 350.21 − 279.17 = 71.04. Because the two ladders agree, the order Gly-Ala-Leu-Phe is supported from both directions. Real spectra are messier, with missing peaks, extra peaks and several charge states, which is why labs use software to match them.
Database matching and de novo sequencing
There are two main ways to interpret MS/MS data:
- Matching against an expected sequence. When the expected sequence is known, as it is for a synthetic peptide, the lab calculates the b and y ions that sequence should give and checks how well the measured peaks match. In larger studies, software searches a database of known sequences in the same way.
- De novo sequencing. The sequence is read directly from the mass differences in the spectrum, with no expected sequence to start from. Newer software, including deep-learning tools, has made this faster, but results still need checking.
Limits of tandem mass spectrometry
- Leucine and isoleucine have the same mass (residue mass 113.08), so standard MS/MS can’t tell them apart. Specialized methods are needed. Edman degradation can tell them apart, because their PTH derivatives elute at different times.
- Near-identical masses. Glutamine (128.06) and lysine (128.09) differ by only about 0.04, so they need a high-resolution instrument to separate.
- Gaps in coverage. Some peptide bonds break poorly, so part of a ladder can be missing and the order in that stretch stays uncertain.
Edman degradation vs tandem mass spectrometry at a glance
| Edman degradation | Tandem MS (MS/MS) | |
|---|---|---|
| Reads from | N-terminus, one residue per cycle | Both ends, from b and y ions |
| Blocked N-terminus | Can’t read | Not a problem |
| Practical length | About 30 to 50 residues | Longer chains are usually cut into shorter pieces first |
| Leucine vs isoleucine | Distinguishes them | Standard methods can’t |
| Mixtures | Hard to interpret | Can handle mixtures |
| Speed | Slow, cycle by cycle | Fast |
Sequencing and the identity result on a COA
On a certificate of analysis, identity (LC-MS) is liquid chromatography with mass spectrometry, used to check that the measured mass matches the expected compound. That is usually an intact-mass check, not a full sequencing run. Our LC-MS identity explainer covers what that result confirms and what it doesn’t. Sequencing goes one step further by reading the order of the residues.
Frequently asked questions
What is peptide sequencing?
It is the process of determining the order of amino acids in a peptide, from the N-terminus to the C-terminus.
How does Edman degradation work?
It removes the N-terminal amino acid one cycle at a time. PITC couples to the free N-terminus, acid cleaves off that residue, and the residue is converted to a PTH derivative and identified by HPLC.
What are b and y ions?
They are the product ions formed when a peptide ion breaks along its peptide bonds in tandem mass spectrometry. b ions keep the N-terminus and y ions keep the C-terminus.
Can mass spectrometry tell leucine from isoleucine?
Not with standard MS/MS, because they have the same mass. Specialized methods or Edman degradation are needed.
Is Edman degradation still used?
Yes, though less often than tandem mass spectrometry. It remains useful for confirming the N-terminal sequence of a pure sample.
Is sequencing on every peptide certificate?
Not always. Many certificates report HPLC-UV purity and LC-MS identity. Check which tests a certificate lists. A certificate reports results for the sample tested. It is not a guarantee for other lots. For other terms, see our research peptide glossary.
Peptix certificates
The peptide lots with a published certificate on our peptide COA lookup page each have a third-party Certificate of Analysis showing the lot number, HPLC-UV purity and LC-MS identity. Where a certificate reports net content, the measured amount is printed on that certificate. For example, you can view the TB-500 10 mg, BPC-157 10 mg or BPC-157 / TB-500 20 mg product with its lot certificate, or browse all research peptides.